Determine the Maximum Axial LOAD "P" that a W 18 x 60 could carry assuming both column ends are fixed and
a) No lateral bracing
b) has lateral bracing at mid height perpendicular to the lenght of column, column lenght lenght is 6m; Fy(column elastic yield stress): 248MPa

choose answer (show solution)
a.1 [url removed, login to view] x 10E3 N
a.2 [url removed, login to view] x 10E3 N

b.1 1285.5 x 10E3 N
b.2 1529.4 x 10E3 N