(EXCERforce gym) Suggestions to Re-Organize two Areas and Make a new Ramp... Architecturally .... Auto Cad Layout only 2D.

In Progress Posted Jan 12, 2016 Paid on delivery
In Progress Paid on delivery

Health club .. EXCERforce

- Need to redraw .

- as Many suggestions to reorganizing two areas until satisfy.

with the reception stairs ramp going to the first floor.

1 -------Toilets, changing and spa area.. (this area is to the right of entrance) bellow Mezzanine.

The Request here is :

A-not less than 5 changing rooms.

B-not less than 6 toilets.

C-not less than 5 shower room.

D-not less than 7 basins.

E-three swimsuit dryer. Attached >

F-one Hot and one cold Jacuzzi (please take sizes as the standards ---for 4-5 people ).

G-one Sauna for 8 people.

H-Steam room for 8 people.

I-one janitor room with floor and regular basin.

J- as much tall locker and bag size locker as possible.

Note: open tops walls for basins or as you suggest..

***** the open walls and areas with less separating walls and more glass doors will ventilate better and more spacious looking area...

####Attachment:

Organizing Mezzanine and toilet [url removed, login to view]

Toilets [url removed, login to view] #####

2 ------- Staff rooms and one meeting room with an office. (This area is above the Toilets,...) ( its the Mezzanine floor).

The Request here is :

A- AS MUCH ROOMS AS POSSIBLE WITH A NICE SPACE FOR TWO STAFF. not big nor small.

B-each room will have two beds above each other with a cabinet for two. no toilet or kitchen inside only a corner with one big fridge (hotel style corner)

C-one bigger room for supervisor a cloth cabinet. with toilet and (a kitchen corner Hotel style)

D- One main office (two tables) with corner Couch. with toilet. and cornered kitchen (hotel style).small fridge.

E- One office with a round meeting table (8 to 10 chairs ).

F- big windows facing the swimming pool and reception sides.

G-Public toilet for all staff with shower and changing (ratio : 3:6:1 for 3 room 6 staff and 1 toilet and 1 separate shower room ).

H-Public Kitchen with BIGGER fridge and Big Freezer and big Oven. one line of cabinet.

I- smaller near ceiling window on neighbor side.

J- least corridors.

K-least wall thickness (to use spaces).

####Attachment:

Organizing Mezzanine and toilet [url removed, login to view]

Pano office staff [url removed, login to view] ####

3 ------ create a ramp slopping , that starts from ground floor by members entering from parking or main entrance or elevator than checking-in than going up by the ramp to the first floor .

going up from ground floor 0m reception area. to 7m first floor gym area...

A- if needed you can put few stairs steps 50mm to 100mm high than start appropriate angle for ramp sloop.

B-You may make a strong Twist for space.

C-you may go over the car parking ramp or fitness area or any...

D- you can make as long as its should for a smooth walking sloop up and down.

E- 1500mm - 1700mm width of sloop ramp.

F- 10 degrees to 16 degrees angle max.

G- If needed you can add 20 degrees 1500mm in the middle of 16 degrees to step up the ramp faster.

H- you suggest the opening on the first floor.

Note : there is 700mm*250mm beam between columns . framing reception areas between column corners.

## Actual images (now): (Reception top [url removed, login to view]) and (ramp [url removed, login to view])

### Need like any of these this attached images:

(ramp for members inclines walking [url removed, login to view])

AutoCAD Building Architecture Civil Engineering Engineering Drawing Structural Engineering

Project ID: #9295990

About the project

20 proposals Remote project Active Jan 13, 2016