Crouzet Controller for a heatpump

Closed

We would like asap a quote for following project on a Crouzet Smart, heatpump application.

Compressor heats boiler (55°C) and water for radiant heating (35°C)

Inputs.

3 NTC probes (if 1 spare available, a 4th probe)

1 contact pressure protection.

On/Off

If spares input available: immediate heat boiler and/or immediate engage electrical heater to support radiant heating.

Output.

Compressor

3 way valve

Electrical heater

Circulation pump (water)

The available M3 Crouzet function block Heating Curve is used to adapt the water temperature to the outside temperature.

Electrical heater is used when radiant water doesn’t reach within a safety time preset temperature.

Heating of the boiler is postponed till lower night rates or immediately heated by a push button.

Once in a week, boiler is postheated by the electrical heater to avoid legionella.

On the screen, we see (eventually by scrolling down)

actual temperature boiler

Actual temperature radiant water temperature

Outside temperature

discharge gas temperature

Set value radiant

Set value Boiler

Actual hour

User can alter on the screen (eventually by scrolling down)

Set water and radiant temperature.

Change clock.

The amplification factor for the heating curve.

If the heat pumps run only on the lower night rates or continuous (on programming level, we will say in the code when lower night rates can be used, Saturday and Sunday are also the whole day lower night rates in Belgium)

When boiler will be heated (the radiant heating is stopped while we heat the boiler)

System stops when discharge temperature reaches overtemperature (set on programming level)

When radiant temperature is at set temperature, pump is stopped and compressors then runs some seconds longer (set on programming level) to pump down partially the system.

What would be the additional cost to make it possible we can monitor this via the www?

Kind regards

Peter

Skills: Engineering, Mechanical Engineering

See more: crouzet heating curve function block, crouzet function block heating curve, crouzet heat curve, crouzet project, what is programming used for, what is c programming used for, what is be electrical engineering, what is a function in programming, sunday night programming, smart input, mechanical engineering cost, make a quote, hour change 2012, function block programming, protection engineering, engineering rates, smart safety, see ELECTRICAL, mechanical pump, m3, heating water, heat engineering, Boiler, application pressure, mechanical push push

Project ID: #2791454

5 freelancers are bidding on average $1840 for this job

bchandra1955

Professional simulation domain expert engineer here.

$2200 USD in 25 days
(49 Reviews)
5.4
betaenergy

Dear Sir, We are Reserach and Development company whose working area are : -Digital Motor Control -Analog Design -Electronic Design -Power Electronics -PCB design -Embedded system -Matlab -Simulation of ha More

$2500 USD in 40 days
(10 Reviews)
4.9
scribblerspk

Kindly see your mail box. Thanks.

$1500 USD in 14 days
(1 Review)
3.9
TarangMehta

hello sir, I have my bachelors in mechatronics and doing my masters in robotics and automation in germany. If the project is to be done in belgium than i myself can come there at the place and give u the desired outp More

$2000 USD in 40 days
(0 Reviews)
0.0
oobretenov

I have experience in PLCs and I could design and implement ladder for you.

$1500 USD in 14 days
(0 Reviews)
3.4
suhasgowda

Hello, I am embedded system engineer and have very good experience.I can design and program according to ur requirements and provide you with documentation.

$2000 USD in 16 days
(0 Reviews)
0.0