Closed
Posted
Paid on delivery
I need an HVAC engineer to document the existing mechanical systems for a 1500 sq. ft. retail store and conduct air quality tests for city code compliance in Eagan, MN. Requirements: - Draw detailed mechanical systems layout - Conduct air tests for: - Ventilation effectiveness - Air flow rates per room - Negative air flow in dog wash area Ideal skills and experience: - HVAC engineering expertise - Familiarity with city codes in Eagan, MN - Ability to interpret and work from detailed architectural plans Please ensure your bid includes relevant experience and any necessary certifications.
Project ID: 40280918
5 proposals
Active 6 days ago
Location: Eagan, United States
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
5 freelancers are bidding on average $973 USD for this job

Hi, I have worked on documenting and evaluating HVAC systems for small commercial spaces such as retail stores and service shops, preparing mechanical layouts and ventilation reports for code compliance. For example, I assisted with airflow testing and ventilation verification for a grooming facility where proper exhaust and negative pressure were required in the wash area. I'd love to share my experiences with you. Best regards, Epa
$990 USD in 5 days
5.2
5.2

Hello, I’ve carefully reviewed your project and can assist with documenting the existing HVAC systems for your 1,500 sq. ft. retail store in Eagan and conducting the required air quality tests. I have experience producing detailed mechanical layouts, verifying ventilation effectiveness, measuring room-specific airflow rates, and assessing negative air flow in designated areas like dog wash stations. All work will follow local city code requirements to ensure compliance and provide clear documentation for your records. I would be happy to discuss your current plans and site conditions directly to plan the inspection and testing efficiently. Maksim
$1,000 USD in 7 days
5.2
5.2

With my expertise in Civil and Structural Engineering and my mastery of AutoCAD, Revit and CAD-based workflows, I bring a versatile skillset that ideally suits your HVAC Compliance and Air Quality Testing requirements. Throughout my career, I have excelled in producing accurate technical drawings and 3D models, which will enable me to quickly document your retail store's existing mechanical systems in granular detail as required. Moreover, I'm well-versed with conducting key air quality tests that you require for City Code compliance. Working in various sectors of the construction ecosystem has instilled in me a deep appreciation for the significance of code adherence. It is this awareness that allows me to deliver precise and code-compliant drawings to my clients, optimizing costs and accelerating project approvals. Understanding the specific City Codes in Eagan, MN is no exception to the diligent manner in which I work - this further adds to my suitability for the task at hand. To summarize, my fast communication, attention to detail, and reliable delivery aligns perfectly with what you're anticipating in this project. By leveraging my skills in Building Design, CAD/CAM, and Civil Engineering alongside a client-centered approach, I am confident that comoletion of your project on time while meeting all your specifications with over-adequate proficiency. Consider partnering with me for a hassle-free project execution.
$1,125 USD in 7 days
3.7
3.7

Hi, I'm a licensed mechanical engineer with extensive experience in HVAC system documentation and indoor air quality testing for commercial spaces, including retail stores in Minnesota. I am familiar with Eagan's city codes and will conduct a thorough assessment of your 1500 sq. ft. retail store's existing mechanical systems. I will produce detailed HVAC layout drawings (plans, sections, equipment schedules) based on your architectural plans and on-site measurements . I will also perform the required air quality tests, including ventilation effectiveness measurements, air flow rates per room (using calibrated hoods or anemometers), and negative air flow verification in the dog wash area—all in compliance with applicable codes (IBC, IMC, and local amendments) . Deliverables include a comprehensive report with test results, compliance statements, and the as-built mechanical system drawings. I'm ready to begin—please share your architectural plans and any existing HVAC documentation. Best regards, Justin
$1,000 USD in 3 days
0.0
0.0

Hi there I am writing to express my interest in providing HVAC engineering services for your 1,500 sq. ft. retail store project in Eagan, MN. With extensive experience in mechanical systems documentation, air quality testing, and local code compliance, I am confident in delivering accurate and comprehensive results for your project. I understand the critical importance of proper ventilation in retail environments, particularly in specialized areas like dog wash facilities. I will ensure all testing protocols meet city code standards and provide clear, actionable documentation for permitting and compliance purposes. Regards
$750 USD in 7 days
0.0
0.0

United States
Member since Mar 6, 2026
$250-750 USD
$30-250 USD
$250-750 NZD
$250-750 AUD
$30-250 NZD
₹1500-12500 INR
₹1500-12500 INR
$1500-3000 USD
$250-750 CAD
£20-250 GBP
₹1500-12500 INR
$250-750 USD
$10-30 CAD
€250 EUR
₹600-1500 INR
₹4000-5000 INR
€250-750 EUR
£20-250 GBP
$250-750 USD
$30-250 AUD