Closed

Configure EnergyPlus FMU for HVAC cosimulation

We have created an OpenStudio building model using as a base the SmallHotel example from ASHRAE with the following modifications:

- Heating systems are now based on water radiator heaters placed in each zone.

- For the cooling system, we placed AirTerminal:SingleDuct:ConstantVolume:CooledBeam objects in each zone and the coils from those objects are connected to a chilled water circuit.

- The occupancy schedules are removed.

- Added a main chilled water loop.

- Added an additional boiler loop for heaters.

The building is co-simulated converting the project to an EnergyPlus IDF and then to a FunctionalMockupUnit (FMU) after adding some additional configuration (ExternalInterface:FunctionalMockupUnitExport related parameters).

The target of this project is to modify the OpenStudio project and create an IDF to make possible the co-simulation of some systems but keeping others controlled by EnergyPlus:

* Variables that we want to co-simulate using the FMU interface:

- Zone occupancy using ExternalInterface schedules.

- Heater water flow rate to simulate a water valve.

- Chilled water flow rate of the CooledBeam coils to simulate a water valve.

- Ventilation flow rate to simulate a VAV box damper.

* Output variables:

- Energy consumption for Heating, Cooling and Ventilation systems.

- Zone Mean Air Temperature.

* Controlled by EnergyPlus:

- Main chilled water loop temperature setpoint.

- Main boiled water loop temperature setpoint.

- Heating and cooling EnergyPlus autosize.

Skills: Building Consulting, Building Design, Mechanical Engineering, Structural Engineering

See more: configure cisco router nat isp, configure mysql php troubleshoot, fedora configure sendmail, configure cisco 800 router dynamic dsl, configure asterisk 118, configure godaddy server, configure web interface cisco, windows server 2003 configure active directory, configure active directory windows, configure centos server, configure webxml tomcat server, configure ias cisco, target markets companies, apache cgi bin configure, configure dynamic nat, carrier hvac revit blocks, configure error preprocessor libcpp fails sanity check lfs, configure asterisk linux, hi i need to configure freepbx and asterisk upon a project we have really quick and easy stuff thanks, We are in urgent need of a website for a firm of consulting engineers based in Canada. Our target audience is

About the Employer:
( 0 reviews ) Valencia, Spain

Project ID: #19245708

6 freelancers are bidding on average €30/hour for this job

rainbow

I am mechanical engineer working in the area of heating and air-conditioning I can work on your project Send details of work

€30 EUR / hour
(8 Reviews)
4.5
anilgudaliya111

Hello sir/mam, I am an engineer. I have read about your project I have 3+ year of experience in design and modelling . i can do it as per your requirements. i'm working till client not satisfy. i am working with More

€31 EUR / hour
(4 Reviews)
3.2
Kornazov

YOUR PROJEKT IS JUST AS IMPORTANT TO ME AS FOR YOU! HELLO THERE. Im an CIVIL ENGINEERING. I CAN: * PROFESSTIONAL DRAW BY AUTOCAD ALL VERSIONS. * DESIGN BUILDING STEEL, CONCRETE,TIMBER BY SAP2000, ETABS, HILT More

€30 EUR / hour
(0 Reviews)
0.0
vspsconsultant

I offer a better understanding & solutions to your problem. we can discuss further in details. Looking forward for the association...

€27 EUR / hour
(0 Reviews)
0.0
€30 EUR / hour
(0 Reviews)
0.0
fadi933

HI there, I am a mechanical engineer with more than 3 years experience working in field of HVAC system design. I have design many complex projects. Pleas have a look on my portfolio . you can see some of my designs. More

€31 EUR / hour
(0 Reviews)
0.0