Water tank with seismic isolators + ANSYS APDL Workbench (COMBIN40 and COMBIN14)

ONLY EXPERTS AND WITH EXPERIENCE IN THIS WORK, do not make me waste my time with people who are learning. VERIFIABLE EXPERIENCE WILL BE REQUIRED. Important documents are attached. Read please

It is necessary to model in Ansys APDL workbench, 2 steel tanks with water inside, one of them without seismic isolation and the other with seismic isolation at the base.

Model in Ansys APDL Workbench a circular steel tank with water. It is necessary to analyze the fluid-structure-seismic isolator interaction.

At the base of the tank with isolator seismic, there are 2 types of seismic isolators, which must be modeled in 3D, with COMBIN40 and COMBIN14 elements depending on the type of seismic isolator. There are 20 "red color" type seismic isolators, and 11 "blue color" type seismic isolators. The hysteresis curve of each type of seismic isolator is represented in red and blue. The location of each seismic isolator is described in one of the images.

For "red color" seismic isolators, lateral hysteresis should be modeled in two directions with COMBIN40 elements and vertical stiffness with COMBIN14 elements.

For "blue color" seismic isolators, lateral hysteresis should be modeled in two directions with COMBIN14 elements and vertical stiffness with COMBIN14 elements.

Concrete slab has only concrete or it is RCC type with compressive strenght of 35 MPa.

The water should be modeled with acoustic elements to obtain the modal analysis and the fundamental frequency, as well as a transient analysis with earthquake.

A modal analysis of the two tanks must be carried out, in addition to determining the percentage of modal participation of each mode for the total response of the structure.

Obtain the impulsive and convective frequency, and compare it in both models.

The convective frequency of the tank without seismic isolation must be equal to the convective frequency of the tank with seismic isolation.

The impulsive frequency of the tank with seismic isolation must be the frequency obtained from the seismic isolators.

Impulsive mode in the tank without seismic isolation, the water on the surface must move quite a bit.

Impulsive mode in the tank with seismic isolation, the water on the surface should NOT move.

The convective mode in the tank with seismic isolation, the water on the surface must move a lot.

The convective mode in the tank without seismic isolation, the water on the surface must move a lot.

What I need in this job, for both models is the following:

• The complete model of both tanks, with seismic isolation, and without seismic isolation. Both verified with the housner model, or some equivalent method. NOTHING CAN BE DONE, IF THE MODELS ARE NOT VERIFIED WITH MANUAL METHODS AND MODAL ANALYSIS.

• Water hydraulic level sloshing observation and consequent pressure distribution monitoring.

• Von misses stress video on the tank wall for acceleration vs. time earthquake.

• Video of the movement of the water for the acceleration vs. time earthquake, observing the sloshing effect.

• Video of the lateral deflection for the acceleration vs. time earthquake.

• Video tutorial on how to run the models and get the results.

• Modal analysis of the tank with seismic isolator. And detect the fundamental period of the seismically isolated tank, the period of the impulsive and convective mode.

• Obtain the hysteresis curve of the two types of seismic isolators, recorded by the analysis with the earthquake.

• Stress and strain analysis due to the earthquake.

• Maximum stresses on the tank wall for an acceleration vs. time input.

• Maximum sloshing height.

• Maximum displacement.

• Video training on how to run the model and how the modeling was done in ANSYS.

• Correctly model the two types of seismic isolators, considering the horizontal and vertical hysteretic behavior.

• A video tutorial on how to edit the earthquake in ANSYS, to be able to enter different earthquakes, including time steps.

Skills: Mechanical Engineering, Finite Element Analysis, Engineering, Ansys

About the Client:
( 0 reviews ) San Pedro de la Paz, Chile

Project ID: #33400708

11 freelancers are bidding on average $1145 for this job

(34 Reviews)
5.9
megiengineers7

Hi there, I am a mechanical engineer with expertise in FEA and CFD. I have 4+ years of experience working on APDL. I have checked the details and I am confident to execute this task. I have already worked on Combi14 a More

$1300 USD in 20 days
(66 Reviews)
6.1
(18 Reviews)
5.4
saleiz2019

Hello dear client I have seen your project detail I am a mechanical engineer with thermal engineering masters I am FEA expert using ANSYS Workbench for more than 8 years I will be honest I haven't done water tank wit More

$850 USD in 5 days
(11 Reviews)
4.6
zahid49ch

Hello, I am mechanical engineer with 5 year industrial experience in design and analysis using Solidworks Ansys abaqus and comsol. Please let me know when you are available to discuss it. Regards

$1200 USD in 7 days
(21 Reviews)
4.1
arvind1329

Hello, I am a professional CAD CAM and CAE design engineer. I am expert in Ansys Apdl. I have 10+ years of experience in simulation. I can complete your task. I hope you contact me as soon as possible. Thankyou regards

$750 USD in 5 days
(27 Reviews)
4.4
AndreyAgeenko

+++TURN YOUR IDEA INTO REALITY+++ I read the job description carefully and believe it has a disruptive, brilliant idea. I can turn your idea into 3d model so that you can go further with your idea. I have been developi More

$1125 USD in 7 days
(3 Reviews)
3.2
Alebg1989

I'm a mechanical engineer and I have worked in South America for metallic structures with sismo (earthquake) accelerations. The procedure is catch the data of earthquake event, (point of horizontal and vertical accele More

$900 USD in 15 days
(3 Reviews)
1.6
Petchimuthu19

I hope done my project with in the week. I can best for you done my project and I am responsible for my project

$1110 USD in 7 days
(0 Reviews)
0.0
NguyenTran1010

Hi Dear I am a skilled FEA expert and have proficient skill of FEA by Ansys. I checked the project details carefully and this project is for FEA of water tank by earthquake load. Such project is my proficient skill and More

$750 USD in 3 days
(0 Reviews)
0.0
VietHungDynamic

Dear sir, Please find the technical proposal through this link: [login to view URL] I have practiced seismic analysis for more than 10 years, using normative or theoretical approaches. I have pub More

$1490 USD in 15 days
(0 Reviews)
0.0